Raid unconfigured good
WebSep 1, 2016 · On my HBA (LSI MegaRAID SAS 9266-8i) and with firmware version 3.460.115-6465 it was necessary to enable JBOD for the controller.Once that was done, all drives not part of a RAID automatically changed from "Unconfigured Good" to JBOD status. WebJul 1, 2015 · Firmware state: Unconfigured (good), Spun Up Device Firmware Level: NA01 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address (0): 0x5000cca02a05a5c1 SAS Address (1): 0x0 Connected Port Number: 0 (path0) Inquiry Data: NETAPP X410_HVIPC288A15NA01LVV338TN FDE Capable: Not Capable FDE Enable: …
Raid unconfigured good
Did you know?
WebNov 11, 2024 · If the previous disk was a virtual disk/RAID volume member, then wait for any RAID rebuild to complete (see step 6 for the command). For SA Warehouse Nodes (MAPR SAW), please refer to the article entitled Security Analytics How to replace faulty disk on RSA Security Analytics Warehouse (SAW) node in RSA Security Analytics 10.3 and higher ... WebJan 20, 2024 · To me that choice should change the drive from being part of an array to being unconfigured, thus available for use in an array. Of course, the terminology they are using confused me before so I could certainly be wrong. View Best Answer in replies below 20 Replies DragonsRule pure capsaicin Dec 22nd, 2016 at 1:56 PM
WebSep 22, 2024 · In the Unconfigured Good window, use the up arrow key or the down arrow key to select Go and then press Enter. In the Warning screen, select Confirm and press the space bar. Select Yes and then press Enter. In the Unconfigured Good window, ensure that the progress field has a value of Rebuild x%, where x indicates percent complete. The … WebAug 10, 2024 · Unconfigured Bad usually means an improperly removed device that has been reconnected? Do you recall anything like that? You can mark it as good but it might start a rebuild so check your RAID status before proceeding to do this.
WebJul 19, 2024 · Their state may show as (Foreign) Unconfigured Good, or (Foreign) Unconfigured Bad. The Foreign state indicates that the Intel RAID controller finds existing RAID configurations on the new drives. ... Because of the RAID-level redundancy, this action should trigger a rebuilding process. 2.3. Wait until the RAID card completes the current ... WebJan 29, 2016 · The new Cisco C240-M4 is comming with a Cisco RAID Controller capable to handle disks in JBOD mode. Unfortunately Cisco delivers new servers with all disks …
WebAug 23, 2024 · When working with a DIP that is configured for RAID 5 and that has suffered a two drive failure, all data that was contained on the virtual drive will be lost. The initial …
WebApr 16, 2024 · Firmware state: Unconfigured(good), Spun Up To get the right Array and Row position of the drive in the RAID array, execute: /opt/MegaRAID/MegaCli/MegaCli64 … nws forcast discussion mnWebSep 22, 2024 · Enter the Dell PERC 9 Configuration Utility by pressing during the post. Click Configuration Management > Convert to Non-RAID Disk. Select Physical Disks to Convert to Non-RAID. Select the physical disk and click OK. A screen is displayed asking if you are sure you want to perform the operation. nws flood outlookWebJul 22, 2024 · To use the the newly installed drives in a RAID array, you need to change them to Unconfigured Good from JBOD: Press Ctrl+G to launch the Intel® RAID BIOS console or … nwsfollowerframeworkWebOct 2, 2014 · Drive state local disk 0: Unconfigured Good Drive state local disk 1: Online Why UCS is not taking local disk 1, which is RAID 1 protected already, rebuild disk 0 and go on with association of the service profile? regards /Hugo 1 person had this problem I have this problem too Labels: Labels: Unified Computing System (UCS) nws flowoodWebFeb 10, 2014 · When the server is power off, after a raid controller replacement or after moving HDDs to another server is commonly see the hard drives in un-configured good. … nws fmWebMar 31, 2024 · I have a raid 5. One of the disks got predictive failure status and then I replaced it with another disk (hot swap). I did not shutdown the machine or reboot. I … nws forecast 06335WebMar 23, 2024 · Identify the disk while the system is running. Turn the system off. Replace the drive. Turn the system back on. It should automatically pick the new drive and use it for the degraded array. If it does not happen, mark the disk as Unconfigured Good. If it is already set as Unconfigured Good, right-click it and select Make Drive Online. nws follower framework